905.665.6888
info@realtechwater.com
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Algae
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • Pesticides
    • BTEX
    • Hydrocarbons
    • Contaminant Alarm
    • Spectral Fingerprint
  • PRODUCTS
    • By Category
      • UV254 Field Meters
      • UV254 Analyzers
      • UV-VIS Sensors
        • PL Series Sensors
        • GL Series Sensors
        • ML Series Sensors
      • Additional Sensors
        • Turbidity Sensor
        • pH Sensor
        • Dissolved Oxygen Sensor
        • Conductivity Sensor
      • Sensor Controllers
        • Smart Sense Controller
        • Real Controller
      • Optional Accessories
        • Clean Systems
        • Pump Clean Systems
        • Air Purge Clean Systems
        • Dilution Systems
        • Dual Feed System
      • Data Analysis
      • show all …
    • By Parameter
      • BOD
      • COD
      • TOC
      • UV254
      • UVT
      • Nitrate
      • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring & Protection
      • Ground Water Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance
      • DBP Formation Potential
      • Nitrification Monitoring
      • Smart Water Networks
    • Municipal Wastewater
      • Sewage Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Biological Nutrient Removal Monitoring
      • UV Disinfection Performance
      • Advanced Treatment Monitoring & Protection
      • Effluent Pollution Management
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Product Loss Monitoring
    • Industrial Wastewater
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • Biological Nutrient Removal Monitoring
      • UV Disinfection Performance
      • Advanced Treatment Monitoring & Protection
      • Effluent Discharge Management
      • Ballast Water Treatment Monitoring
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

Real UV254 M Series Analyzers

PARAMETERS

UVT, UV254, DOC, TOC, Colour

mail_outlineRequest a Quote
Overview
Specifications
Models & Range
Accessories
Downloads
Overview

Real Tech’s UV254 Online analyzers offer an affordable and accurate solution for real-time UV254 or UVT monitoring. Benefiting from Split-Sense Pro and patented Ortho-beam technology, the need for calibration is limited lowering maintenance requirements. Several path length options provide solutions for wastewater to high purity applications.

  • Real-time UV254 or UVT organics analysis
  • Accurate and reliable data
  • Simple to install and operate
  • Low maintenance, bypass style design
  • 4 line x 20 character backlit LCD display
  • Optional automatic chemical cleaning systems
  • 2-year limited warranty
Specifications

CHARACTERISTICTECHNICAL DATA
ParametersUVT or UVA
Accuracy± 0.5% FS
Unitscm-1 or %
Path Lengths1 mm, 2 mm, 4 mm, 10 mm, 10 mm x 20 mm, 50 mm, 100 mm, 150 mm, 250 mm
Sampling Time10 seconds
CalibrationIn-situ zeroing to any sample with known UVT. No further calibration required.
CleaningIn-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.
Self-DiagnosticDetection and diagnosis of internal system fault
Operator InterfaceFive push buttons to control a comprehensive hierarchical menu system
Display4 line x 20 character backlit LCD with LED alarm indicator
AlarmsDry contact terminals allow operator configurable alarms for: high and low UVT/UVA set points, low lamp output, leak detected, system fault, etc.
Humidity ControlHumidity sensor with large regeneratable desiccant system
OutputsSelf-powered 4-20mA, RS232 serial for PC
Wavelengths253.7nm
Light SourceLow-pressure mercury UV lamp / UV LED
Lamp Life2 years
Dimensions17"H x 14"W x 8"D
EnclosureNEMA 4X, wall mountable
Flow Rate300 - 1000 mL/min
Pressure Rating20 PSI
Fluid Connections1/4" tube push-in fittings
Electrical24VDC 40W power adapter (accepts 90-250VAC 50/60Hz)
Storage Temp-20 to 60°C (-4 to 140°F)
Operating Temp0 to 45°C (32 to 113°F)
Weight22 lbs
Warranty2-year limited warranty
TechnologyOrtho-Beam and Split-Sense Pro

Models & Range
MODELUVT (%) UV254 (Abs/cm) PATH LENGTHPRICE
M20100-100 0 – 13 1 mmRequest a Quote
M20200-100 0 - 6.5 2 mmRequest a Quote
M20400-100 0 - 3.25 4 mm Request a Quote
M21005-1000 - 1.3 10 mm Request a Quote
M300015-1000 – 1 10 mm x 20 mm Request a Quote
M405055-100 0 - 0.26 50 mm Request a Quote
M410074-1000-0.13100 mmRequest a Quote
M415082-1000-0.09150 mmRequest a Quote
M425089-1000 - 0.05 250 mm Request a Quote
Accessories
  • Cleaning Systems
  • Pump Clean Systems
  • Pump Systems
  • Dual Feed System
Downloads

Specification Sheet for Real UV254 Analyzers

APPLICATIONS FOR UV254 ANALYZERS

Source Water Monitoring

Coagulation Optimization

Contaminant Removal Efficiency

DBP Formation Potential

UV Disinfection Performance

Smart Water Networks

Wastewater UV Disinfection Performance

Process Water Control

Cooling Water Contamination

Boiler Feedwater Impurities

Ultrapure Water Monitoring

Product Loss Monitoring

Water Reuse Optimization

Wastewater UV Disinfection Performance

Ballast Water Treatment Monitoring

CONTACT
1150 Champlain Court, Whitby, Ontario L1N 6K9
1.877.779.2888
905.665.6888
905.665.7025
info@realtechwater.com
Facebook
Twitter
LinkedIn
YouTube
RESOURCE CENTER

FAQ

Downloads

CLIENT LOGIN





Not a client? Contact Us

Accessibility Policy

© 2017 Real Tech Inc. All rights reserved.