905.665.6888
info@realtechwater.com
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Algae
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254 Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Algae Sensor
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensor
      • Multi-Wave Sensors
      • Nitrate Sensors
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Pro
      • Real Controller
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Air Purge Clean Systems
      • Dilution Systems
      • Air Clean Systems
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

REAL TOC SENSOR

OL SERIES

Parameter(s): TOC, DOC

mail_outlineRequest a Quote
OVERVIEW
SPECIFICATIONS
MODELS & RANGE
CONTROLLERS & ACCESSORIES
DOWNLOADS
OVERVIEW

TOC SENSOR

Real Tech’s bypass TOC sensor provides affordable real-time measurement of organic matter in water or wastewater. The sensor provides superior measurement performance across multiple wavelengths of light using UV LEDs. Designed to meet the needs of many monitoring applications, the OL series offers multiple sensor path length selections to meet the desired measurement range.

FEATURES & BENEFITS

  •  Affordable real-time TOC monitoring
  • Multiple wavelength sensor uses UV LED technology for superior measurement performance
  • Wastewater to high purity measurement ranges
  • Operator friendly, low maintenance UV LED design
  • Reagent free optical measurements
  • Simple to install and operate
SPECIFICATIONS

CHARACTERISTICTECHNICAL DATA
Path Lengths1 mm, 2 mm, 4 mm, 8 mm, 25 mm, 50 mm, 100 mm, 150 mm
ParametersTOC, DOC,
RangeDepends on model selected. Refer to range chart
UnitsParameter specific (mg/L, cm-1 or PCU)
Sampling Time30 seconds
CalibrationFactory calibrated. Field adjustment of calibration is possible
CleaningIn-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.
Self-DiagnosticDetection and diagnosis of internal system fault
AlarmsDry contact terminals allow operator configurable alarms for:
high and low set points, low lamp output, leak detect, system fault, etc.
Humidity ControlHumidity sensor with large regeneratable desiccant system
WavelengthsMultiple wavelengths
Light SourceUV LED
Flow Rate300 - 1000 mL/min
Pressure Rating20 PSI maximum
Fluid Connections1/4" OD tube push-in fittings
Electrical/Comm.From controller
Storage Temp-20 to 60°C (-4 to 140°F)
Operating Temp0 to 45°C (32 to 113°F)
EnclosureNEMA 4X, wall mountable
Weight22 lb (2000 series) or 24 lb (4000 series)
Dimensions17"H x 14.25"W x 7.5"D (2000 series) or 17.75"H x 15.5"W x 6.75"D (4000 series)
Warranty2-year limited warranty (Extended care packages available)
Sensor UpgradesHigh Temp. Upgrade I, High Temp. Upgrade II

* Technical Specifications are subject to change without notice.

MODELS & RANGE

OL series models include TOC sensor, flow cell, calibration bottle and dehumidifier. Controller and accessories sold separately.

MUNICIPAL

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 400Request a Quote
OL20202 mm0 - 200Request a Quote
OL20404 mm0 - 100Request a Quote
OL21008 mm0 - 50Request a Quote
OL402525 mm0 - 16Request a Quote
OL405050 mm0 - 8Request a Quote
OL4100100 mm0 - 4Request a Quote
OL4150150 mm0 - 2.5Request a Quote

DAIRY

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 1250Request a Quote
OL20202 mm0 - 625Request a Quote
OL20404 mm0 - 300Request a Quote
OL20808 mm0 - 150Request a Quote

BEVERAGE

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 3000Request a Quote
OL20202 mm0 - 1500Request a Quote
OL20404 mm0 - 750Request a Quote
OL20808 mm0 - 375Request a Quote

BREWERY

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 3000Request a Quote
OL20202 mm0 - 1500Request a Quote
OL20404 mm0 - 750Request a Quote
OL20808 mm0 - 375Request a Quote

MEAT PROCESSING

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 1250Request a Quote
OL20202 mm0 - 625Request a Quote
OL20404 mm0 - 300Request a Quote
OL20808 mm0 - 150Request a Quote

PULP & PAPER

MODEL#PATH LENGTHTOC/DOC (mg/L)PRICE
OL20101 mm0 - 250Request a Quote
OL20202 mm0 - 125Request a Quote
OL20404 mm0 - 60Request a Quote
OL20808 mm0 - 30Request a Quote

* Stated ranges are approximate, dependent on industry, site and application – contact Real Tech to confirm model selection.
* Higher maximum range possible with use of Dilution System option.

CONTROLLERS & ACCESSORIES

CONTROLLERS

PRODUCT#NAMEDESCRIPTION
S-169000Real ControllerWall mounted controller with 4-line x 20-character back lit LCD display
S-11TPCReal Controller ProWall mounted controller with touch panel PC interface (PC inside cabinet model)
S-11TPCDReal Controller ProWall mounted controller with touch panel PC interface (PC external on door model)

ACCESSORIES

UVT-078130Real Clean System IAutomatic chemical cleaning system for use with 2000 series models
UVT-118010Real Clean System IIAutomatic chemical cleaning system for use with 4000 series models
S-1789121Dual Feed System IIDual feed option includes Digital I/O module for use with controllers
DOWNLOADS

TOC Sensor Specification Sheet – Real Tech

SIMPLE, PLUG & PLAY TOC MONITORING

Real Tech’s bypass TOC sensor is a cabinet style instrument installed directly on a wall, railing or system backboard. Sample is supplied to the sensor from a pressurized source or alternatively, from an open-channel using an accessory pumping/cleaning system. The sensor must be connected to a Real Tech controller for operation.

EXAMPLE CONFIGURATION

  • Real Controller
    For affordable, user friendly operation and control
  • TOC Sensor
    For real-time continuous TOC organics measurement
  • Real Clean System
    For low maintenance automatic cleaning

Multiple sensors can be added to Real Tech’s controllers to expand water quality monitoring capabilities.

Simple to install, easy to operate, no reagents and no waiting for lab results.

QUOTE THIS SYSTEM

LIQUID AI COMPATIBLE

Our Liquid Ai data services complement our real-time quality monitoring systems. Calibration Health Monitoring ensures accuracy and reliability are maintained so our clients can have the utmost confidence in their results, while our Remote Monitoring platform enables access to data anywhere, anytime.

1150 Champlain Court, Whitby, Ontario L1N 6K9
1.877.779.2888
905.665.6888
905.665.7025
info@realtechwater.com
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.