+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

WHAT IS UV254?

February 25, 2017Real Tech

UV254 is a water quality test parameter that provides a quick measurement of the organic matter in water. The measurement technique works by shining ultraviolet light (UV) light at 254 nm through a quartz cells that contains a representative water sample. Most commonly, the cell is 1 cm (10 mm) but can vary dependent on the application and water quality.

Organic compounds, specifically those that contain aromatic rings or unsaturated carbon bonds (double or triple) in their molecular structure, absorb a portion of the UV light as it passes through the water sample. Since the intensity of the light source is known, a detector on the other side of the cell is used to measure the amount of light absorbed by organic compounds present in the sample.

UV254 is typically expressed as either UV absorbance (UVA) per cm (cm-1) or UV transmittance (UVT) %. In some cases, UV254 is referred to as Spectral Absorption Coefficient (SAC254).

UV254 and UVT are both valuable water quality measurement for many applications, including UV disinfection performance monitoring, raw water monitoring for event detection, coagulation control, and DBP precursor monitoring. The method for measurement is simplistic and does not involve the use of reagents. There are multiple ways in which UV254 or UVT can be measured including; continuously in real-time with a bypass analyzer or submersible probe sensor, grab samples throughout the plant with a portable test meter, or in laboratory with a test meter or benchtop spectrophotometer.

Discover more about Real Tech’s practical and affordable UV254 instruments.

________________________________________________________________________________________________________________________
RELATED POSTS

HOW A SIMPLE ORGANICS MONITOR HELPED REDUCE CHEMICAL COSTS

HOW A SIMPLE ORGANICS MONITOR HELPED REDUCE CHEMICAL COSTS

The Ridgway Water Treatment Plant (WTP) in Elk County Pennsylvania uses a Real Tech Real UV254 online analyzer to achieve a...
Read More
SPECIFIC ULTRAVIOLET ABSORBANCE (SUVA) AND UV254

SPECIFIC ULTRAVIOLET ABSORBANCE (SUVA) AND UV254

Specific ultraviolet absorbance (SUVA) provides a general characterization of the nature of natural organic matter (NOM) in a water sample...
Read More
CASE STUDY: PUERTO RICO WTP SAVES THOUSANDS WITH UV254

CASE STUDY: PUERTO RICO WTP SAVES THOUSANDS WITH UV254

The Los Filtros Guaynabo Water Treatment Plant in Puerto Rico installed a Real UV254 M3000 analyzer to monitor raw water...
Read More

GO BACK TO BLOG

 

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.