+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

CASE STUDY: FUTURE OPERATORS GAIN EXPERIENCE WITH SIMPLE ORGANICS TEST METER

January 19, 2016Real Tech

PREPARING FUTURE WATER & WASTEWATER TREATMENT PLANT OPERATORS

Linn-Benton Community College in Oregon, USA is preparing students for careers as water or wastewater treatment plant operators with a variety of “hands-on” labs, such as jar testing, designed by program head Ron Sharman. The focus of the labs is to give students experience with a variety of operator tasks similar to those encountered daily by a treatment plant operator. Sharman has seen a lot of change in the water industry over his long tenure as a professor in this field. Although UV254 organic testing has long been a known alternative to the more traditional TOC organic analysis, there hasn’t been practical equipment available on the market until more recently, limiting the use of this water quality parameter.

That has all changed now, with both portable and real time UV254 analyzers readily available at affordable price points that are very easy to operate. This has
opened up the opportunity for Sharman to include more hands-on organic analysis training in his program which will benefit his students in the future as operators. The increasing role of UV254 testing is becoming even more apparent with tightening budgets and regulations to minimize the formation of disinfection by-products (DBPs). Another reason for the increasing role of UV254 is its bias towards detecting reactive organic matter, which is problematic for plants as it is the reactive organics that more readily consume coagulants and combine with chlorine to form DBPs.

OPTIMIZING COAGULATION TO REMOVAL ORGANICS EFFICIENTLY

UV254 meter jar testingMonitoring UV254 is allowing plant operators to better control and optimize their treatment processes and produce improved water quality. Many plants just don’t have the capability to run TOC lab samples at a high frequency given the time and expense, nor do they have the available budget to purchase and maintain more costly online TOC analyzers. As a result, Sharman sees operators simply bypassing TOC analyzers and tracking UV254 in real-time for process control. As an addition to his infield labs, Sharman uses the Real UV254 P200 portable meter to help his students learn about coagulation optimization. By understanding the organic load of a specific water source, the students are able to determine the optimum coagulation dosage of alum.

HANDS ON EXPERIENCE WITH UV254 AND JAR TESTING

UV254 jar testingIn October 2011, Sharman had his students participate in an infield lab, testing the water of the North Santiam River in Stayton, Oregon. The goal of the lab was to determine the optimum coagulation dosage for alum and possibly soda ash for this water source. The students conducted various jar tests with UV254 to determine which chemical combination would produce the best finished water quality results. Using the Real UV254 P200 portable meter, the students were able to measure the organics level both before and after the addition of chemicals to determine efficiency of various doses. As with many water sources, the North Santiam river’s water quality conditions can fluctuate, requiring changes in treatment decisions. After a heavy rainfall, the effects on organic matter on coagulant demand were very apparent and enabled the students to see the important of frequent or real-time data for optimizing the coagulant dose.

UV254 AND COLOUR

In addition to UV254 jar testing labs, the students undertake experiments to further understand the correlations that can be made between different parameters such as UV254 and TOC or COD, or UV254 and colour. Professor Sharman prepared colour samples in the lab and measured the apparent color units of each sample along with the UVA values. From this simple experiment the students were able to see the correlation between ACU and UV254. Essentially, UV254 will detect any organics detected by a colour instrument. However, UV254 has the added advantage that it is more sensitive to organics than color instruments. It is also able to detect organics that don’t have any color, such as pesticides, which could be in the water and would be missed by color instruments.

________________________________________________________________________________________________________________________
RELATED POSTS

HOW A SIMPLE ORGANICS MONITOR HELPED REDUCE CHEMICAL COSTS

HOW A SIMPLE ORGANICS MONITOR HELPED REDUCE CHEMICAL COSTS

The Ridgway Water Treatment Plant (WTP) in Elk County Pennsylvania uses a Real Tech Real UV254 online analyzer to achieve a...
Read More
ORGANICS AREN’T INVISIBLE: A GUIDE FOR SIMPLE ONLINE MONITORING

ORGANICS AREN’T INVISIBLE: A GUIDE FOR SIMPLE ONLINE MONITORING

Control of dissolved organics has been one of the highest priority concerns for most water treatment plants for over 20 years....
Read More
A GUIDE TO SOURCE WATER MONITORING

A GUIDE TO SOURCE WATER MONITORING

The purpose of source water monitoring is to enable drinking water treatment facilities to identify changes in water quality, implement treatment...
Read More

GO BACK TO BLOG

 

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.