+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

CASE STUDY: UVT ANALYZER HELPS WTP SAVE 50% IN ENERGY COSTS

September 30, 2019Real Tech

UV254 drinking waterA Water Treatment Plant (WTP) in Ontario, Canada produces high quality, safe drinking water for over 90,000 residence despite a challenging water source. The plant pumps water from the Grand River which spans 300 kilometers from Dufferin County, discharging into the north shores of Lake Erie. The WTP resides in the lower watershed with approximately 21 municipal wastewater treatment facilities upstream, influencing raw water quality at the plant intake. To help manage this unstable water source with high organic matter, the WTP operations team relies on UV254.

DOWNLOAD CASE STUDY

Background

UV254 is a simple surrogate test to estimate natural organic matter (NOM) or total organic carbon (TOC) concentration in water. Organic matter in the water will react with chlorine to form disinfection by-products (DBPs), specifically trihalomethanes (THMs) and haloacetic acids (HAAs). In addition, organic matter absorbs light at 254 nm and is therefore important to monitor for ultraviolet (UV) disinfection. Understanding the importance of UV254, the operators at the WTP use instrumentation from Real Tech to monitor organics throughout.

Treatment of the raw water consists of screening before the addition of Polyaluminum chloride (PACl) for coagulation and flocculation with an Actiflo® system. Pre-treatment is followed by ozonation and biological filtration, with a multi-barrier approach to disinfection using both chlorination and UV before discharge to the clearwell.

WTP Manages Organics Removal and UV Disinfection Performance with UV254

The operators perform UV254 (UVA) organics testing twice daily with the Real Tech UV254 portable meter at four sampling points in the plant. These grab samples allow the operators to evaluate raw water UVA concentration as well as the effluent UVA concentration of each treatment process. In doing so, the team has identified the systems capacity to remove organics under ideal operating conditions. On average, a 50% UVA removal can be achieved with the coagulation/flocculation process and an additional ~20-30% UVA removal is obtained from the ozonation/biological filtration process.

The plant has also installed a real-time UV254 analyzer from Real Tech prior to UV disinfection that serves two key purposes. The first is for UV transmittance monitoring (UVT) that enables the plant to perform real-time dose calculations to flow pace. This provides an approximate 50% reduction in power usage in comparison to operating without flow pacing. Secondly, the analyzer provides the operators with real-time insights on organics concentration prior to chlorination.

Ensuring Compliance for DBPs

Ontario Drinking Water Standards regulate total THM levels to 100 ug/L calculated as a running average. To limit the formation potential of THMs, an effluent UV254 set point of 0.08 UVA in the summer and 0.10 UVA in the winter has been established based on past historical trending between UV254 and THMs. Monitoring the finished water UVA allows the plant to make adjustments to optimize coagulant dose for organics removal. If the raw water organics concentration is low, resulting in a finished UVA well below the 0.08 or 0.1 set point, the operator can decrease the PACl dose to save on chemical costs. Alternatively, finished water UVA approaching the set points would require an increase in PACl dose to enhance organics removal.

Simple and Reliable UV254 Drinking Water Solutions

The simplicity and reliability of the Real Tech UV254 drinking water instruments make optimizing the process for organics removal practical for the operators. Having monitored UVA for several years, the team is able to make PACl dose adjustments to optimize UVA removal while ensuring goals for turbidity and pH are also achieved. Thanks to a progressive, forward thinking operations team, the WTP consistently meets Ontario Drinking Water standards for DBPs and produces high quality, safe drinking water for consumers.

______________________________________________________________________________________________________________________

RELATED POSTS

FAQ: BYPASS SENSOR OR SUBMERSIBLE PROBE

FAQ: BYPASS SENSOR OR SUBMERSIBLE PROBE

UVT PRODUCT SELECTION QUICK QUIDE When it comes to real-time UV transmittance (UVT) analysis, Real Tech provides two primary forms...
Read More
UV TRANSMITTANCE 101: EVERYTHING YOU NEED TO KNOW ABOUT UVT

UV TRANSMITTANCE 101: EVERYTHING YOU NEED TO KNOW ABOUT UVT

ABOUT UVT UV transmittance, UV transmission or UVT is a measurement of the amount of ultraviolet light (commonly at 254...
Read More
CASE STUDY: ACCURATE AND RELIABLE UVT FOR NEARLY A DECADE

CASE STUDY: ACCURATE AND RELIABLE UVT FOR NEARLY A DECADE

A surface water treatment plant (WTP) in Ohio has successfully used six Real Tech Real UV254 online analyzers in their...
Read More
1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.