+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

REAL CHROMIUM VI SENSOR

CRL SERIES

Parameter(s): Chromium VI

mail_outlineRequest a Quote
OVERVIEW
SPECIFICATIONS
MODELS & RANGE
CONTROLLERS & ACCESSORIES
DOWNLOADS
OVERVIEW

CHROMIUM VI SENSOR

Real Tech’s bypass Chromium VI sensor provides affordable real-time measurement of chromium VI in water or wastewater. The sensor provides superior measurement performance across multiple wavelengths of light using UV LEDs. Designed to meet the needs of many monitoring applications, the CRL series offers multiple sensor path length selections to meet the desired measurement range.

FEATURES & BENEFITS

  • Affordable real-time chromium VI monitoring
  • Multiple wavelength sensor uses UV LED technology
    for superior measurement performance
  • Wastewater to high purity water measurement ranges
  • Operator friendly, low maintenance design
  • Quick and simple optical measurements
  • Reagent free operation
SPECIFICATIONS

CHARACTERISTICTECHNICAL DATA
Path Lengths1, 2, 4, 8 mm (2000 series)
25, 50, 100, 150 mm (4000 series)
ParametersChromium VI
Range Depends on model selected. Refer to range chart
Accuracy± 1% full scale
Unitsmg/L, ppm
Sampling Time30 seconds
CalibrationFactory calibrated. Field adjustment of calibration is possible.
CleaningIn-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.
Self-DiagnosticDetection and diagnosis of internal system fault
AlarmsDry contact terminals allow operator configurable alarms for:
high and low set points, low lamp output, leak detect, system fault, etc.
Humidity ControlHumidity sensor with large regeneratable desiccant system
WavelengthsMultiple wavelengths
Light SourceUV LED
Flow Rate300 - 1000 mL/min
Pressure Rating20 PSI maximum
Fluid Connections1/4" OD tube push-in fittings
Wetted MaterialsKynar, Polyethylene, Quartz, SS 316L, Viton
Electrical/Comm.From controller
Ambient Temp.0 to 45°C (32 to 113°F)
Water Temp.0 to 90°C (32 to 194°F) at 21°C (69.8°F) Ambient temperature
EnclosureNEMA 4X, wall mountable
Weight22 lb (2000 series)
24 lb (4000 series)
Dimensions17"H x 14.25"W x 7.5"D (2000 series)
15.82”H x 13.82”W x 9.00”D (4000 series)
Warranty2-year limited warranty (Extended care packages available)

* Technical Specifications are subject to change without notice.

* Water temperature range based on material compatibility only. Contact Real Tech to verify application.

MODELS & RANGE

SENSOR SELECTION

MODEL SERIESDESCRIPTION
2000Ideal for general water monitoring applications
4000Ideal for high purity water monitoring applications

SENSOR MODELS & RANGE

CRL series models include chromium VI sensor, flow cell, calibration bottle and dehumidifier. Controller and accessories sold separately.

MODEL#PATH LENGTHCHROMIUM VI (mg/L)
pH 9 or higher
CHROMIUM VI (mg/L)
pH 6-9
CHROMIUM VI (mg/L)
pH 3-6
PRICE
CRL10050.5 mm0 - 2880 - 4000 - 576Request a Quote
CRL10101 mm0 - 1440 - 2000 - 288Request a Quote
CRL10202 mm0 - 720 - 1000 - 144Request a Quote
CRL10404 mm0 - 360 - 500 - 72Request a Quote
CRL20101 mm0 - 1440 - 2000 - 288Request a Quote
CRL20202 mm0 - 720 - 1000 - 144Request a Quote
CRL20404 mm0 - 360 - 500 - 72Request a Quote
CRL20808 mm0 - 180 - 250 - 36Request a Quote
CRL402525 mm0 - 60 - 80 - 12Request a Quote
CRL405050 mm0 - 30 - 40 - 6Request a Quote
CRL4100100 mm0 - 1.50 - 20 - 3Request a Quote
CRL4150150 mm0 - 10 - 1.50 - 2Request a Quote

* Stated ranges are based on testing in deionized water. Interfering substances that may be present in the water may reduce the upper end of the measuring range. Please contact Real Tech to confirm model selection.
* Higher maximum range possible with use of Dilution System option.

CONTROLLERS & ACCESSORIES

CONTROLLERS

PRODUCT#NAMEDESCRIPTION
S-229005Real Controller LiteWall mounted controller with 4-line x 20-character back lit LCD display.
Includes modbus RTU (RS485).
S-169000Real ControllerWall mounted controller with 4-line x 20-character back lit LCD display.
Includes modbus RTU (RS485), 1 channel of 4-20 mA out and digital I/O module.
S-11TPCReal Controller ProWall mounted controller with 12.1” colour LCD touch panel PC interface (PC inside cabinet model).
Includes Modbus RTU and Modbus TCP.
S-11TPCDReal Controller ProWall mounted controller with 12.1” colour LCD touch panel PC interface (PC external on door model).
Includes Modbus RTU and Modbus TCP.

ACCESSORIES

PRODUCT#NAMEDESCRIPTION
UVT-078130Real Clean System IAutomatic chemical cleaning system for use with 2000 series models
UVT-118010Real Clean System IIAutomatic chemical cleaning system for use with 4000 series models
S-178121Dual Feed System IIDual feed option includes Digital I/O module for use with controllers
DOWNLOADS

Chromium VI Sensor Specification Sheet – Real Tech

SIMPLE, PLUG & PLAY CHROMIUM VI MONITORING

Real Tech’s bypass Chromium VI sensor is a cabinet style instrument installed directly on a wall, railing or system backboard. Sample is supplied to the sensor from a pressurized source or alternatively, from an open-channel using an accessory pumping/cleaning system. The sensor must be connected to a Real Tech controller for operation.

EXAMPLE CONFIGURATION

  • Real Controller
    For affordable, user friendly operation and control
  • Chromium VI Sensor
    For real-time continuous chromium VI measurement
  • Real Clean System
    For low maintenance automatic cleaning

Multiple sensors can be added to Real Tech’s controllers to expand water quality monitoring capabilities.

Simple to install, easy to operate, no reagents and no waiting for lab results.

QUOTE THIS SYSTEM

LIQUID AI® COMPATIBLE

Our Liquid Ai® data services complement our real-time quality monitoring systems. Calibration Health Monitoring ensures accuracy and reliability are maintained so our clients can have the utmost confidence in their results, while our Remote Monitoring platform enables access to data anywhere, anytime.

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.