+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

REAL NITRITE ANALYZER

N2 SERIES

Parameter(s): Nitrite

Request a Quote
OVERVIEW
SPECIFICATIONS
MODELS & RANGE
ACCESSORIES
DOWNLOADS
OVERVIEW

NITRITE ANALYZER

Real Tech’s Nitrite analyzer provides rapid real-time measurement of nitrite (NO2) in water. The Nitrite analyzer utilizes light at various wavelengths for measurement. Continuous nitrite monitoring can bring significant value to many applications especially for boilers, chillers and aquaculture.

FEATURES & BENEFITS

  • Affordable real-time nitrite (NO2) monitoring
  • Multiple wavelength analyzer with LED technology
  • Operator friendly, low maintenance design
  • Built-in controller
  • Quick and simple optical measurements
  • Reagent free operation
SPECIFICATIONS

CHARACTERISTICTECHNICAL DATA
Path Lengths2, 4, 8 mm (2000 series)
25, 50, 100, 150 mm (4000 series)
ParametersNitrite (NO2)
RangeDepends on model selected. Refer to range chart
Accuracy± 1% FS
Unitsmg/L, ppm
Sampling Time30 seconds
CalibrationFactory calibrated. Can be field adjusted if needed.
CleaningIn-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.
Self-DiagnosticDetection and diagnosis of internal system fault
Operator InterfaceFive push buttons to control a comprehensive hierarchical menu system
Display4 line x 20 character backlit LCD with LED alarm indicator
AlarmsDry contact terminals allow for operator configurable alarms for:
high and low set points, low lamp output, leak detected, system fault, etc.
Humidity ControlHumidity sensor with large regeneratable desiccant system
OutputsSelf-powered 4-20mA, RS232 serial for PC
WavelengthsUV and visible light wavelengths
Light SourceLED
Flow Rate300 - 1000 mL/min
Pressure Rating20 PSI maximum
Fluid Connections1/4" OD tube push-in fittings
Wetted MaterialsKynar, Polyethylene, Quartz, SS 316L, Viton
Electrical24VDC 40W power adapter (accepts 90-250VAC 50/60Hz)
Ambient Temp.0 to 45°C (32 to 113°F)
Water Temp.0 to 90°C (32 to 194°F) at 21°C (69.8°F) Ambient temperature
Storage Temp-20 to 60°C (-4 to 140°F)
EnclosureNEMA 4X, wall mountable
Weight22 lb (2000 series)
24 lb (4000 series)
Dimensions17”H x 14.25”W x 7.5”D (2000 series)
17.75”H x 15.5”W x 6.75”D (4000 series)
Warranty2-year limited warranty (Extended care packages available)
Analyzer UpgradesCell Modem, Dual Transmitter

* Technical Specifications are subject to change without notice.

* Water temperature range based on material compatibility only. Contact Real Tech to verify application.

MODELS & RANGE

ANALYZER SELECTION

MODEL SERIESDESCRIPTION
2000Ideal for general water monitoring applications
4000Ideal for high purity water monitoring applications

ANALYZER MODELS & RANGE

N2 series models include nitrite analyzer, flow cell, calibration bottle, dehumidifier and standard power supply. Automatic chemical cleaning system and additional accessories sold separately.

MODEL#PATH LENGTHNO2-N (mg/L)NO2 (mg/L)PRICING
N220202 mm15 - 300050 - 10,000Request a Quote
N220404 mm7.5 - 150025 - 5000Request a Quote
N220808 mm3.75 - 75012.5 - 2500Request a Quote
N2402525 mm1.2 - 240 4 - 800Request a Quote
N24050 50 mm 0.6 - 120 2 - 400 Request a Quote
N24100100 mm0.3 - 601 - 200Request a Quote
N24150 150 mm0.2 - 40 0.7 - 130 Request a Quote

* Stated ranges are approximate, dependent on industry, site and application – contact Real Tech to confirm model selection

ACCESSORIES
PRODUCT#NAMEDESCRIPTION
UVT-078130Real Clean System IAutomatic chemical cleaning system for use with 2000 series models
UVT-118010Real Clean System IIAutomatic chemical cleaning system for use with 4000 series models
UVT-079121Pump Clean System ISelf-priming pump and automatic chemical cleaning for use with 2000 series models
UVT-129122Pump Clean System IISelf-priming pump and automatic chemical cleaning for use with 4000 series models
UVT-078120Dual Feed System IDual feed upgrade to monitor two water sample lines with one analyzer
DOWNLOADS

Nitrite Analyzer N22000 Series Specification Sheet – Real Tech

Nitrite Analyzer N24000 Series Specification Sheet – Real Tech

APPLICATIONS FOR NITRITE MONITORING

Process Water Control

Cooling Water Contamination

Boiler Feedwater Impurities

Water Reuse Optimization

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.