+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

DATA MANAGEMENT PC SOFTWARE

Real Tech’s Liquid Ai® Data Management PC Software program expands sample and data model (calibration) management capabilities for our new UV-VIS LED portable field meters, putting the power of data into the hands of the user.

The intuitive software allows users the ability to access additional starter data models, update existing data models, and automatically build new custom data models for any site-specific monitoring location desired in one user-friendly program. Users can add to their site-specific data models over time, increasing accuracy and robustness of measurement.

1. Start sampling with your meter

When you start using your new meter from Real Tech, it’s ideal to take a sample and save the reading on your meter any time you collect a sample to send for lab analysis. The saved data can be uploaded later from your meter to the Liquid Ai® Data Management PC Software.

2. Connect your meter to your PC

Connect your meter via the mini-USB to export one or all saved samples from your meter to the Liquid Ai® PC Software and start the process of gaining greater sample and data management capabilities.

3. Compare, Build and Improve your Data Models

Input your time stamped lab samples to the corresponding saved meter samples. The Liquid Ai® PC Software will enable you to see the percent error and R2 value of the data model created against the lab results. From here, you can build upon your site-specific data model to create more robust, accurate and reliable results.

Operators are empowered with our innovative Liquid Ai® automatic data model builder. Build and improve upon your data models to customize to your site-specific conditions for confidence in your results.

4. Load and Go

Now that you have your new customized data model for your targeted monitoring location, you can upload it onto your portable meter and head out into the field to test anytime with confidence.

5. Validate and Keep Building

Remember you can validate your sample results anytime by saving them on your meter and checking against time stamped lab data when it becomes available. You can also continue to build robustness and accuracy in your meter results by adding additional lab samples to your data model anytime, so it only improves over time giving you the reliability you need to take control and know what’s in your water.

Download Liquid Ai® Data Management PC Software Specification Sheet

Download
1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.