+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

SPECTRAL ABSORPTION

Spectral absorption is a measurement of the amount of ultraviolet and/or visible (UV-VIS) light absorbed by a water sample of a given path length. Absorbance is directly proportional to the concentration of matter in the sample.

Ultraviolet and/or visible light is passed through a quartz cell containing the sample water. The intensity of attenuated light is measured with a sensor at a single wavelength or at multiple wavelengths.

Spectrophotometry

WHAT CAN BE MEASURED WITH SPECTRAL ABSORPTION TECHNOLOGY?

There are several different types of matter, such as organics and nitrates that naturally absorb light in distinct regions of the UV-VIS wavelength spectrum. Using absorbance data in combination with laboratory data for a target parameter or contaminant, it is possible to build a relationship or “calibration” from the two data sets.

This calibration can then be used by an online spectral absorbance instrument to continuously convert the real-time measured absorbance data into a representative milligrams per liter (mg/L) value of the parameter or contaminant of interest. The method allows for laboratory quality data to be obtained in real-time for many common water quality parameters, such as:

  • BOD
  • COD
  • TOC
  • DOC
  • UV254
  • UVT
  • Colour
  • NO3
  • NO2
  • Algae
  • Permanganate
  • Chromium VI
  • Oil in Water
  • Diesel Fuel
  • BTEX
  • Pesticides
  • Herbicides
  • Dyes
  • TSS
  • Contaminant Alarm
  • Spectral Fingerprint

HOW ACCURATE IS THE CORRELATION?

The accuracy of the measurement is highly dependent on the strength of the calibration. Real Tech takes a custom approach to calibrations by using data collected from the local site to ensure high quality results for our clients. Custom or local calibrations are far more reliable and robust in comparison to global calibrations, as they incorporate all relevant information that influences the matrix of the sample. The local calibration is audited periodically to validate the relevance of the calibration to ensure accuracy. The audited data can continually be added to the calibration set, furthering the robustness of the calibration.

ONLINE WATER QUALITY MONITORING SOLUTIONS

Solutions to meet your water quality monitoring needs.

REQUEST A QUOTE

APPLICATION LINKS

  • Municipal Drinking Water
  • Municipal Wastewater 
  • Industrial Process Water
  • Industrial Wastewater
1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.