+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

UV TRANSMITTANCE (UVT)

UV transmittance, UV transmission or UVT is a measurement of the amount of ultraviolet light (commonly at 254 nm due to its germicidal effect) that passes through a water sample compared to the amount of light that passes through a pure water sample. The measurement is expressed as a percentage, % UVT.

WHY IS IT IMPORTANT?

Measurement of UV Transmittance is important for ultraviolet (UV) disinfection of drinking water, wastewater and process water. Low-pressure UV disinfection systems disinfect water using monochromatic UV light at the 254 nm wavelength. The effectiveness of a UV disinfection system is determined by the dose that the system is able to deliver to the target microorganisms in the water. The effective UV dose is dependent primarily on the combined effects of the UV light intensity, the exposure time and the UVT.

UV Transmission varies over time and from site to site as it is related to the quantity of organics, colloidal solids and other material in the water which absorb and scatter the UV light as it passes through the water column. In a UV disinfection system, if the UVT of the water is low, then the UV light is not able to penetrate the water as effectively, thereby reducing the potency of the dose. For this reason, it is very important to monitor UVT and ensure its levels are maintained above the manufacturer’s minimum for proper disinfection to occur.

Large drinking water and process water UV disinfection systems are often also designed with a method that allows the UV dose delivery to be calculated based on UV intensity, flow rate, and UVT, such as the USEPA UVDGM calculated dose approach method. Online UVT measurement is required for a calculated UV dose strategy to make accurate adjustments that result in proper disinfection.

The USEPA UVDGM, DVGW, and ÖNORM UV intensity set-point approach is common for small UV disinfection systems. While this approach does not enable calculated dosing, UVT monitoring is often still incorporated into the system as UVT is a valuable tool for quickly diagnosing operational problems, thus saving the operator time.

HOW TO MEASURE UVT

To measure UVT, ultraviolet light (commonly at 254 nm) is passed through a 10 mm quartz cell containing the sample water. The intensity of attenuated light is measured with a sensor, and compared to that of a pure water sample. The instrument then reports the value as a percentage.

Real Tech has the solutions to help our clients get the information they need, when they need it.

Discover our UV transmittance solutions here:

  • Portable Field Meter
  • Bypass Online Analyzer
  • Submersible Online Probe

UVT INSTRUMENTATION

Real Tech offers a complete line of UVT monitoring and testing solutions.

Learn More
CASE STUDY: ACCURATE AND RELIABLE UVT FOR NEARLY A DECADE

CASE STUDY: ACCURATE AND RELIABLE UVT FOR NEARLY A DECADE

A surface water treatment plant (WTP) in Ohio has successfully used six Real Tech Real UV254 online analyzers in their...
Read More
CASE STUDY: UVT ANALYZER HELPS WTP SAVE 50% IN ENERGY COSTS

CASE STUDY: UVT ANALYZER HELPS WTP SAVE 50% IN ENERGY COSTS

A Water Treatment Plant (WTP) in Ontario, Canada produces high quality, safe drinking water for over 90,000 residence despite a...
Read More

APPLICATION LINKS

  • UV Disinfection Performance 
  • Wastewater UV Disinfection Performance 
  • Ultrapure Water Monitoring
  • Water Reuse Optimization
  • Ballast Water Treatment Monitoring

Explore all applications >

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.