+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

DISSOLVED ORGANIC CARBON (DOC)

Dissolved Organic Carbon or DOC is a measurement of the amount of organic matter in water that can be passed through a filter, commonly 0.45 µm.

HOW WE MEASURE DOC IN REAL TIME

Real Tech’s innovative reagent free DOC sensors utilizes patent-pending and proprietary technologies to provide superior measurement performance across multiple wavelengths of light using UV LEDs. Many compounds absorb light in the UV-VIS spectrum including organic compounds. The sensors measure organics in a multi-dimensional way that results in improved correlations to aggregate organics water quality parameters, such DOC and TOC. This also allows the sensors to be able to detect changes in the composition of organics independently of their concentration. Real Tech’s affordable, plug & play real-time TOC/DOC solutions are advancing wastewater management.

Learn more about our real-time TOC/DOC monitoring solutions>

IMPORTANCE OF DOC FOR DRINKING WATER

For drinking water, Dissolved Organic Carbon is an important water quality parameter measured for several purposes. Elevated levels of DOC may interfere with the effectiveness of disinfection processes such as UV, ozone and chlorination thus should be monitored for removal prior to disinfection. In plants that disinfect with chlorine, DOC concentrations are a primary concern due to the harmful by-products that form when chlorine reacts with organic matter. DOC in finished water can lead to aesthetic problems and increase the potential for bacterial regrowth in the distribution system. Regulations for DOC are specific to each country, with aesthetic objective in drinking water being approximately 5 mg/L. Additionally, DOC is used in the calculation of SUVA which determines the aromatic portion of DOC, a major precursor for THM formation.

DELAYED LAB RESULTS LIMIT ACTION

Relying on grab samples leads to significant delays. When results come back from the lab, the information is usually of little value for process control and improving plant performance. The DOC procedure requires that the sample be passed through a 0.45 um filter prior to analysis. The test involves converting all organic carbon in a water sample to carbon dioxide (CO2) by utilizing heat and oxygen, chemical oxidants or UV radiation. The resultant CO2 concentration is measured with an infrared analyzer and reported as organic carbon (mg/L). The test takes 5-10 minutes to yield results in the lab, with continuous reagent-based on-line analyzers also available.

Plants need a practical reagent less solution that delivers continuous information to operations personnel. Real Tech has the solutions to help our clients get the information they need, when they need it. Discover our real-time TOC/DOC monitoring solutions here.

ONLINE DOC MONITORING

Real-time DOC monitoring solutions for drinking water.

REQUEST A QUOTE
ORGANICS AREN’T INVISIBLE: A GUIDE FOR SIMPLE ONLINE MONITORING

ORGANICS AREN’T INVISIBLE: A GUIDE FOR SIMPLE ONLINE MONITORING

Control of dissolved organics has been one of the highest priority concerns for most water treatment plants for over 20 years....
Read More

APPLICATION LINKS

  • Source Water Monitoring & Protection
  • Coagulation Optimization
  • Contaminant Removal Efficiency
  • DBP Formation Potential
  • Smart Water Networks
  • Process Water Control
  • Cooling Water Contamination
  • Boiler Feedwater Impurities
  • Ultrapure Water Monitoring
  • Water Reuse Optimization

Explore all applications >

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.