+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

Category: APP NOTE

Home Blog
drinking water coagulation

COAGULATION OPTIMIZATION WITH UV254 OR UV-VIS SPECTRAL ABSORBANCE

April 6, 2022Real Tech

Drinking water plants that use surface water or groundwater under the influence of surface water are susceptible to high levels of organic matter in the raw water. Reduction of organic matter through coagulation/ sedimentation and filtration plays a critical role…

REAL-TIME NITRITE DETECTION FOR HOT WATER BOILERS AND COOLING SYSTEMS

June 30, 2021Real Tech

In closed low-pressure water heating and cooling systems, sodium nitrite is a commonly used inhibitor that prevents oxygen related corrosion. It inhibits corrosion by promoting formation of protective films on surfaces. When nitrite is used as a corrosion inhibitor, it…

IDENTIFY AND REDUCE PRODUCT LOSS USING REAL-TIME ORGANICS MONITORING

June 8, 2021Real Tech

LOST PRODUCT = LOST REVENUE Manufacturers in the food and beverage industry lose significant quantities of product in the production process. In the dairy industry, milk losses are on average 2-3% of total production and can be even higher for…

REAL-TIME DETECTION OF SHOCK LOADING EVENTS IN WASTEWATER

October 31, 2019Real Tech

Wastewater quality can change drastically and quickly – particularly in the case of industrial discharges – to generate shock loads within the wastewater treatment system. In addition to potential operational problems such as increased chemical and aeration demand, shock loading…

DRINKING WATER PERMANGANATE DOSE OPTIMIZATION

August 2, 2019Real Tech

Although an effective treatment aid, residual permanganate in your treated water is undesirable and often leads to consumer complaints when pink water pours out of their tap. Careful control of permanganate dosing can be achieved with real-time permanganate monitoring, resulting…

ORGANICS AREN’T INVISIBLE: A GUIDE FOR SIMPLE ONLINE MONITORING

May 24, 2019Real Tech

Control of dissolved organics has been one of the highest priority concerns for most water treatment plants for over 20 years. Organics monitoring is an even more critical issue today in the face of more stringent regulations and concerns around trace organics,…

DETECT NITRIFICATION WITH SPEED AND CONFIDENCE

March 4, 2019Real Tech

PARAMETERS TO MEASURE IN THE DISTRIBUTION SYSTEM Nitrite, nitrate, total chlorine, monochloramine, free chlorine, ammonia, TOC, pH, temperature OVERVIEW Nitrification events can be costly to remediate and harm your community’s trust in their water supply. Catching nitrification early and reliably lets you…

OPTIMAL NUTRIENT DOSE FOR WASTEWATER TREATMENT

January 19, 2019Real Tech

PARAMETERS TO MEASURE FOR NUTRIENT DOSING IN WASTEWATER BOD, COD, TOC, TSS OVERVIEW Nutrient dosing in wastewater must be carefully controlled to ensure a favorable nutrient ratio is achieved, resulting in good quality effluent. Real-time online monitoring of organic loading…

AERATION OPTIMIZATION IN WASTEWATER

January 4, 2019Real Tech

PARAMETERS TO MEASURE FOR AERATION OPTIMIZATION BOD, COD, TSS, DO OVERVIEW A significant portion of a wastewater treatment plant’s energy costs are due to aeration operations (~45-75% of the total energy). The required aeration rate of a biological treatment system…

A GUIDE TO SOURCE WATER MONITORING

October 12, 2018Real Tech

The purpose of source water monitoring is to enable drinking water treatment facilities to identify changes in water quality, implement treatment strategies based on the characteristics of the water, optimize the treatment processes, and take preventative actions to protect the source water…

Posts pagination

1 2 >
1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.