+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

Category: WASTEWATER

Home Blog Page 2

CASE STUDY: LOUISIANA PAPER MILL RECOVERY OF VALUE STREAMS

July 31, 2018Real Tech

A pulp and paper mill in Louisiana, USA, was reliant on daily grab samples for detection of spill events which was found to be inadequate for proper  management of the treatment processes. Real Tech proposed a customized solution that would…

RECOVERY OF VALUE STREAMS

July 24, 2018Real Tech

PARAMETERS TO MEASURE UNINTENDED LOSS IN WASTEWATER BOD, COD, TOC, TSS, Industry specific compounds OVERVIEW Several industries, including dairies, juice concentrate, breweries, as well as pulp and paper, lose significant quantities of materials with recoverable value in their waste streams….

CASE STUDY: REAL-TIME BOD/COD MONITORING INCREASES REVENUE FROM PRODUCT RECOVERY

March 31, 2018Real Tech

A dairy plant in Minnesota was reliant on daily BOD and COD grab samples for detection of product loss. This method was inadequate for proper management and the plant required a better solution to meet their needs. Real Tech provided…

REDUCING PRODUCT LOSS TO WASTEWATER

March 23, 2018Real Tech

PARAMETERS TO MEASURE FOR PRODUCT LOSS BOD, COD, TOC, TSS, Industry specific compounds OVERVIEW Several industries lose significant quantities of product in their waste streams including dairies, juice concentrate, breweries, as well as pulp and paper. Product lost to drain…

CONTAMINANT DETECTION IN WASTEWATER

March 20, 2018Real Tech

PARAMETERS TO DETECT CONTAMINATION BOD, COD, TOC, BTEX  Dyes, surfactants, black liquor OVERVIEW In industries such as pulp and paper, textiles, petrochemical and pharmaceutical, toxic or difficult to treat contaminants can end up in the waste stream. Not being able…

THE IMPORTANCE OF UV TRANSMITTANCE FOR UV DISINFECTION APPLICATIONS

November 4, 2017Real Tech

BENEFITS OF REAL-TIME MONITORING UV disinfection performance assurance Dose pacing for energy savings OVERVIEW UV disinfection for water treatment or wastewater treatment is a process where a system disinfects water using UV light to damage the DNA of microorganisms in…

Posts pagination

< 1 2
1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.