+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

REAL CLEAN SYSTEMS

mail_outlineRequest a Quote
OVERVIEW
SPECIFICATIONS
MODELS
DOWNLOADS
OVERVIEW

Real Tech’s automatic chemical cleaning systems offer the most effective method for cleaning optical sensors. Brushes and wipers rely on moving parts that often wear over time and are ineffective at removing tough fouling. Cleaning fluid and frequency can be set to site specific needs, ensuring the target fouling agents are removed effectively and drift is minimized. The automatic cleaning cycles save time and lower maintenance while improving overall operation and accuracy of the instrument.

FEATURES & BENEFITS

  • For use with pressurized sample water (300-1000 ml/min)
  • Automatic preprogrammed cleaning cycles
  • Limits flow cell fouling and enhances performance
  • Saves time and lowers maintenance
  • 1 L cleaning fluid container
  • 2-year limited warranty
SPECIFICATIONS
CHARACTERISTICTECHNICAL DATA
Cleaning Frequency User configurable
Cleaning Capacity1L storage container, cleaning fluid recapture feature reduces fluid replenishment frequency
Min Flow Rate300 mL/min
Max Flow Rate1000 mL/min
Max Pressure20 PSI
AlarmsLeak, Cleaning Fluid Low, Cleaning Fluid Empty
Electrical/CommunicationFrom controller/ analyzer
Dimensions12.0”H x 14.0”W x 7.5”D (Real Clean System I) or 13.75”H x 16.0”W x 7.5”D (Real Clean System II)
EnclosureNEMA 4, wall mountable
Fluid Connections1/4" tube push-in fittings
Storage Temp. -20 to 60°C (-4 to 140°F)
Operating Temp.0 to 45°C (32 to 113°F)
Weight10 lbs.
Warranty2-year limited warranty
MODELS

NAMEDESCRIPTIONMODEL #PRICE
Real Clean System IAutomatic chemical cleaning system for use
with 2000 and 3000 series models
UVT-078130Request a Quote
Real Clean System IIAutomatic chemical cleaning system for use
with 4000 series models
UVT-118010Request a Quote

DOWNLOADS

Real Clean System Specification Sheet – Real Tech Inc.

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.