+1 905.665.6888
[email protected]
Facebook
Twitter
LinkedIn
YouTube
  • COMPANY
    • Who We Are
    • Why Choose Us
    • Who We Work For
    • Client Testimonials
  • PARAMETERS
    • BOD
    • COD
    • TOC
    • DOC
    • UV254
    • UVT
    • Nitrate
    • Nitrite
    • TSS
    • Permanganate
    • Chromium VI
    • Colour and Dyes
    • THM / HAA
    • Ozone
    • Benzene
    • BTEX
    • Hydrocarbons
    • Hydrogen Peroxide
    • Contaminant Alarm
    • Spectral Fingerprint
    • Turbidity
    • show all …
  • PRODUCTS
    • Meters
      • BOD/COD Meter
      • Multi-Wave Meter
      • TOC/DOC Meter
      • UV254/UVT Meter
    • Analyzers
      • Colour Analyzer
      • Free Chlorine Analyzer
      • Nitrite Analyzer
      • TSS Analyzer
      • UV254 Analyzer
    • Sensors
      • Ammonium Sensor
      • Ammonium Probe
      • Benzene Sensors
      • BOD/COD Sensors
      • Chromium VI Sensors
      • Colour Sensors
      • Conductivity Probe
      • Dissolved Oxygen Probe
      • Free Chlorine Sensor
      • Hydrocarbons Sensors
      • Multi-Wave Sensors
      • Nitrate Sensor
      • Nitrate/Nitrite Sensors
      • Nitrite Sensors
      • Ozone Sensors
      • Permanganate Sensor
      • pH/ORP Probe
      • Spectrum Sensors
      • Surfactants Sensor
      • TOC Sensors
      • TSS Sensors
      • Turbidity Probe
      • UV254 Sensors
      • UVT Probe
    • Controllers
      • Real Controller Lite
      • Real Controller
      • Real Controller Pro
    • Accessories
      • Clean Systems
      • Pump Clean Systems
      • Pump Clean Pro System
      • Probe Clean System
      • Compressed Air System
      • Dual Feed Systems
    • Data Services & Software
      • Remote Monitoring
      • Calibration Health
      • Anomaly Detection
      • Data Management PC Software
    • Product Selection Guide
    • show all …
  • APPLICATIONS
    • Municipal Drinking Water
      • Source Water Monitoring
      • Blending Optimization
      • Coagulation Optimization
      • Contaminant Removal Efficiency
      • UV Disinfection Performance and Optimization
      • DBP and Formation Potential Monitoring
      • Smart Water Networks
      • Nitrification Monitoring
    • Municipal Wastewater
      • Influent Wastewater Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Wastewater
      • Product Loss Monitoring
      • Chemical Dose Optimization
      • Aeration Optimization
      • Nutrient Dose Optimization
      • UV Disinfection Performance and Optimization
      • Advanced Treatment Monitoring
      • Effluent Discharge Monitoring
    • Industrial Process Water
      • Process Water Control
      • Cooling Water Contamination
      • Boiler Feedwater Impurities
      • Ultrapure Water Monitoring
      • Water Reuse Optimization
      • Ballast Water Treatment Monitoring
  • RESOURCES
    • News
    • Blog
    • Downloads
    • FAQ
  • CONTACT US
    • Contact Us
    • Request a Quote
    • Product Registration
    • Careers

DBP AND FORMATION POTENTIAL MONITORING

Chemical disinfection can cause the formation of harmful byproducts when disinfectants like chlorine react with naturally occurring compounds such as organic matter in water. The most well known and regulated disinfection byproducts (DBPs) are Trihalomethanes (THMs) and Haloacetic acids (HAA5) which can have adverse health effects if exposed at high concentrations. In order to limit the formation of these harmful byproducts, it’s essential to understand and monitor the precursors.

READ CASE STUDY

GAIN THE INFORMATION YOU NEED:

Monitoring organic matter in real time, specifically UV254, provides one of the best indicators for a water’s potential to form DBPs. Absorbance at 254 nm indicates the concentration of organic molecules with aromatic groupings. Aromatic organics and chlorine tend to form higher DBP levels, thus real-time measurement of UV254 provides a predictor for formation potential and an indicator for the need to further enhance organic (TOC) removal. In addition, water quality can be assessed prior to distribution and at key locations in the distribution system to directly monitor the level of THMs and HAAs.

• Compliance with MCL for THMs and HAA5s
• Improved treated water quality
• Reduced chlorine dosing for residual concentration requirements
• Improved public safety

PRODUCTS:

UVT monitor, UVT analyzer

REAL UV254 ONLINE ANALYZER

Parameters Measured:
UV254, TOC, DOC

LEARN MORE

REAL UV254 FIELD METER

Parameters Measured:
UV254

LEARN MORE

REAL MULTI-WAVE SENSOR

Parameters Measured:
THM, HAA

LEARN MORE

1150 Champlain Court, Whitby, Ontario L1N 6K9
+1 905.665.6888
Toll Free US and Canada:
1.877.779.2888
+1 905.665.7025
[email protected]
Facebook
Twitter
LinkedIn
YouTube

Real Tech Blog

Downloads

News

 

 

Partner Portal Login

Accessibility Policy

Privacy Policy

© 2017 Real Tech Inc. All rights reserved.